Humidity Generators / Calibrators : Rotronic HygroGen2



The HygroGen HG2 humidity generator can be used for the calibration of up to five relative humidity probes simultaneously. The HG2 humidity generator typically requires less than 5 minutes to equilibrate from one humidity condition to another when temperature is kept constant. This is accomplished by using a mixed flow method to precisely generate a known humidity and temperature condition within a well insulated chamber. A desiccant cartridge provides low humidity and a saturator provides high humidity. These are mixed together by a control system to create stable humidity within the range of 5 to 95 %RH. Temperature is controlled with a thermoelectric heat pump and can be set within the range of 0 to 60 °C.

The HG2 humidity generator is a self-contained unit that requires no external resources except mains power. It can also be used together with an external chilled mirror reference instrument. The HG2 features a user friendly touch screen graphical interface as well as a programmable ramp and soak function with multiple steps and profiles. The HG2 humidity generator is pre-loaded with the ROTRONIC HW4-P data acquisition software which is used for calibrating and adjusting the ROTRONIC humidity temperature probes and instruments.

Operation

  • Generates conditions within the range of 0 to 60°C and 5 to 95 %RH
  • Extremely stable humidity and temperature environment
  • Fast equilibrium: typically less than 5 min. from one condition to another
  • Accepts up to five humidity-temperature probes simultaneously

Design

  • Mixed flow with desiccant dryer cell and piezoelectric humidifier
  • Peltier thermoelectric element with radial chamber mixing fan
  • Smart chamber design minimizes temperature and humidity gradients
  • Internal RTD for temperature control and reference
  • Function to correct RTD to match HygroClip 2 probe temperature data
  • Electronic monitoring of the water level and desiccant condition with on-screen indication
  • Integrated UV water sterilization system
  • Two standard door models: 15mm or 30mm adjustable ports to suit almost any probe diameter
  • Heated internal sample loop for connection with a chilled mirror reference instrument

Embedded PC

  • Embedded PC for configuration, control and automated functions
  • Fully functional ROTRONIC HW4-P software with data acquisition, calibration and adjustment functions for HygroClip probes
  • Solid State Disk (SSD)
  • Integrated nine port USB hub for connecting ROTRONIC USB probe adapters and peripherals such as mouse and keyboard
  • RJ-45 Ethernet Port
  • Intuitive, easy-to-use touch screen graphical user interface
  • DVI - Monitor out for external display
  • User upgradable firmware

Automated Calibration

  • User programmable ramp and soak function with up to 200 steps per profile
  • Up to 20 different profiles
  • Integrated ROTRONIC HW4 software for the calibration and adjustment of HygroClip probes


 